【BRP series】Full-automatic perfusion bioreactor system
【BRP series】Full-automatic perfusion bioreactor system
Process Control Automation
发酵系统及生物反应器
The Correspondence between Process Automation Design and Risk Assessment
发酵系统及生物反应器
The design of network framework depends on the risk assessment of URS and automation system, and the best control solution will be developed after comprehensive consideration.
● Redundant backup of data servers for security increase of GMP data
● Controller redundancy and communication link redundancy of CPU and IO slave for stability advance of control link
● Highly scalable system with OPC communication interface reserved
● Convenient post-maintenance, hot swappable supported by remote IO module, and non-stop module replacement
Network Framework of Process Control
发酵系统及生物反应器
Process Control Automation
Process Control Automation
The Correspondence between Process Automation Design and Risk Assessment
The Correspondence between Process Automation Design and Risk Assessment
Risk(0-5) | |
Controller Failure | 5 |
I/O Module Failure | 2 |
Interface and Communication | 4 |
Data Loss | 5 |
Network Failure | 5 |
Instruments Failure | 2 |
Valves Failure | 2 |
Procedure Error | 3 |
Electromagnetic Interference | 1 |
The design of network framework depends on the risk assessment of URS and automation system, and the best control solution will be developed after comprehensive consideration.
● Redundant backup of data servers for security increase of GMP data
● Controller redundancy and communication link redundancy of CPU and IO slave for stability advance of control link
● Highly scalable system with OPC communication interface reserved
● Convenient post-maintenance, hot swappable supported by remote IO module, and non-stop module replacement
The design of network framework depends on the risk assessment of URS and automation system, and the best control solution will be developed after comprehensive consideration.
● Redundant backup of data servers for security increase of GMP data
● Controller redundancy and communication link redundancy of CPU and IO slave for stability advance of control link
● Highly scalable system with OPC communication interface reserved
● Convenient post-maintenance, hot swappable supported by remote IO module, and non-stop module replacement
Network Framework of Process Control
Network Framework of Process Control
News
Contact Us
Products
News
COPYRIGHT (©) 2019 河北三德济辰生物科技股份有限公司
冀公网安备 13019902000542号 冀ICP备18031899号-1
Products
News
Contact Us
Focus us and learn more
Products
News
Foucs on our Wechat and learn more
Santa-Jichen
Tel: +86 0311 83118162
Email: sales@santa-jichen.com
Address: Room 1612, Building 1, No.136 Huanghe Avenue, Shijiazhuang Science and Technology Center, shijiazhuang, Hebei Province
COPYRIGHT (©) 2019 河北三德济辰生物科技股份有限公司 冀ICP备18031899号-1
COPYRIGHT (©) 2019 河北三德济辰生物科技股份有限公司 冀ICP备18031899号-1